Configuring Main System

1


Configuring Global Recording Parameters

Let’s start with the options on the General Setting tab:

[Startup] The Startup options instruct the system to enable selected features at system startup.

„ Start Monitor: Select one of the following monitor control modes at system startup:

~ Monitor All: Allows you to monitor all cameras and I/O (if available) at system startup. It is the

same as to manually click Monitor button (No. 16, Figure 1-2) and select Start All Monitoring.

(For details, see Start/Stop Monitoring later in this chapter).

~ Schedule Monitor: Allows you to monitor cameras by schedule. Alternatively you may click

Schedule button and select Schedule Start (No. 15, Figure 1-2). Refer to Recording

Schedule later in this chapter.

~ I/O Monitor: Allows you to monitor all I/O devices. Alternatively you may click the Monitor

button (No. 16, Figure 1-2), and then select I/O Monitoring.

Note: To set different recording modes and alert methods for each camera, see [Monitor Control],

Adjusting Individual Camera later in this chapter.

„ Multicast Server: Allows connection to IP Multicast (one of the remote application) at system

startup. (Or click the Network button (No. 11, Figure 1-2) and select Multicast Server.)

„ TCP Server: Allows connection to Remote View (another remote application) by TCP. (Or click

the Network button (No. 11, Figure 1-2) and select TCP Server.)

„ WebCam Server: Allows connection to WebCam Server at startup. (Or click the Network button

(No. 11, Figure 1-2) and select WebCam Server.)

„ Modem Server: Allows connection to Remote View by a modem. (Or click the Network button

(No. 11, Figure 1-2) and select Modem Server.)

„ Connect to VSM: Allows connection to VSM Server (Or click the Network button (No. 11, Figure

1-2) and select Connect to VSM.)

„ Twin Server: Allows connection to Twin Server at startup. (Or click the Network button (No. 11,

Figure 1-2) and select Twin Server). For more details, see Twin DVR System in Chapter 10.

„ Connect to CenterV2: Allows connection to CenterV2. (Or click the Network button (No. 11,

Figure 1-2) and select Connect to CenterV2.)

„ Enable Directdraw Overlay: Enables full-screen at startup. (For the related applications, see

Switching to Full-Screen View later in this chapter).

„ Enable De-interlace Render: Avoids interlace of the odd and even video lines. This feature

affects only single view mode with the resolution of 640 x 480 and 720 x 480. After enabling the

feature, you must restart the GV-System to apply it.