N-files, Pccc object – Rockwell Automation 22-COMM-C ControlNet Adapter User Manual

Page 134

Advertising
background image

C-16

ControlNet Objects

The adapter supports the following PCCC command types:

See DF1 Protocol and Command Set Manual, Allen-Bradley Publication
No. 1770-6.5.16

.

N-Files

PCCC Object

(Continued)

CMD

FNC

Description

0x06

0x03

Identify host and some status

0x0F

0x67

PLC-5 typed write

0x0F

0x68

PLC-5 typed read

0x0F

0x95

Encapsulate other protocol

0x0F

0xA2

SLC 500 protected typed read with 3 address fields

0x0F

0xAA

SLC 500 protected typed write with 3 address fields

0x0F

0xA1

SLC 500 protected typed read with 2 address fields

0x0F

0xA9

SLC 500 protected typed write with 2 address fields

0x0F

0x00

Word range read

0x0F

0x01

Word range write

N-File

Description

N40

This N-file lets you use Emulated Block Transfer to send many types of
messages. To use Emulated Block Transfer messages, you send a Write
message to N40:0 – N40:63, wait until the adapter responds with a reply
message, and then read the response data in N40:0 – N40:63 with a Read
message.

For details about Block Transfer messages and the data required for each
byte in the N-File, refer to the Remote I/O Adapter User Manual, Publication
20COMM-UM004….

Bits 15 to 8 are the Most Significant Byte. Bits 7 to 0 are the Least Significant
Byte.

Write

Read

Bits 15

0 15

0

N40:0

0x00

Length (in Bytes) 0x00

Length (in Bytes)

N40:1

DSI Port

(1)

(1)

Use the following DSI Port Assignment table to determine the value for the DSI port.

0x81

Status Size

Status Type

N40:2

0x00

CIP Service

Data
(length varies based on message)

N40:3

CIP Class

N40:4

CIP Instance

N40:5

CIP Attribute

N40:6

Data
(length varies based on message)

N40:63