C-18

ControlNet Objects

N-Files (Continued)

PCCC Object

(Continued)

N-File

Description

N44

For Multi-Drive Mode Only

This N-file lets you read and write control I/O messages. You can write
control I/O messages only when all of the following conditions are true:

• The adapter is not receiving I/O from a scanner. For example, there is

no scanner on the network, the scanner is in idle (program) mode, the
scanner is faulted, or the adapter is not mapped to the scanner.

• The value of N42:3 is set to a non-zero value.

Write

Read

N44:0

Drive 0 Logic Command

Drive 0 Logic Status

N44:1

Unused

Unused

N44:2

Drive 0 Reference

Drive 0 Feedback

N44:3

Drive 1 Logic Command

Drive 1 Logic Status

N44:4

Drive 1 Reference

Drive 1 Feedback

N44:5

Drive 2 Logic Command

Drive 2 Logic Status

N44:6

Drive 2 Reference

Drive 2 Feedback

N44:7

Drive 3 Logic Command

Drive 3 Logic Status

N44:8

Drive 3 Reference

Drive 3 Feedback

N44:9

Drive 4 Logic Command

Drive 4 Logic Status

N44:10

Drive 4 Reference

Drive 4 Feedback