Using the I/O

The terms input and output are defined from the controller’s point of
view. Therefore, output I/O is data that is produced by the controller and
consumed by the adapter. Input I/O is status data that is produced by the
adapter and consumed as input by the controller. The I/O image table
will vary based on the configuration of the adapter:

• Operating Mode Jumper J7 (

Figure 2.1

)

Parameter 12 - [DSI I/O Cfg]

The image table always uses consecutive words starting at word 0.

Figure 5.1

and

Figure 5.2

illustrate examples of a Single drive I/O image

(16-bit words) for ControlLogix and PLC-5 controllers respectively.

Figure 5.1 Single Drive Example of I/O Image for ControlLogix

Figure 5.2 Single Drive Example of I/O Image for PLC-5

Single mode is the typical configuration, where one node consists of a
PowerFlex 40 or PowerFlex 400 drive with a 22-COMM-C adapter. For
Multi-Drive mode, where one node can consist of up to 5 drives, refer to

Chapter 7

,

Using Multi-Drive Mode

.

Understanding the I/O Image

Controller

Scanner

Adapter

Word and I/O

PowerFlex 40 Drive

ControlNet

DSI

Output
Image
(Write)

Input
Image
(Read)

Message

Handler

Message

Buffer

0 Pad Word
1 Pad Word
2 Logic Status
3 Feedback

Logic Status
Feedback

Message

Handler

0 Logic Command
1 Reference

Logic Command
Reference

Controller

Scanner

Adapter

Word and I/O

PowerFlex 40 Drive

ControlNet

DSI

Output
Image
(Write)

Input
Image
(Read)

Message

Handler

Message

Buffer

0 Logic Status
1 Feedback

Logic Status
Feedback

Message

Handler

0 Logic Command
1 Reference

Logic Command
Reference