Plc-5 example, Plc-5 example -8 – Rockwell Automation 22-COMM-C ControlNet Adapter User Manual

Page 58

Advertising
background image

5-8

Using the I/O

The Drive I/O Control program (

Figure 5.4

) defines the I/O needed to

control the drive.

PLC-5 Example

Figure 5.4 PLC-5 Ladder Logic Example for Drive I/O Control

In this example, an operator station is wired into the local PLC-5/40C rack as follows:

O:000/0 Drive Ready
O:000/1 Drive Active
O:000/2 Drive Forward
O:000/3 Drive Reverse
O:000/4 Drive Faulted
O:000/5 Drive At Speed
O:001 Operator Speed Feedback

I:000/0 Stop (Normally
I:000/1 Start (Normally Open Pushbutton)

Open Pushbutton)

I:000/2 Jog (Normally Open Pushbutton)
I:000/3 Clear Faults (Normally Open Pushbutton)
I:000/4 Forward / Reverse Selector Switch
I:001 Operator Speed Reference

In this example, a PowerFlex 40 drive with installed 22-COMM-C ControlNet adapter is mapped as follows:

N9:0 Logic Status N10:0 Logic Command
N9:1 Speed Feedback N10:1 Speed Reference

Rungs 0000 through 0005 move the Logic Status from the drive to the operator station.

0000

N9:0

0

Drive Logic Status
READY

O:000

0

Operator
Drive Ready Status
Display

0001

N9:0

1

Drive Logic Status
ACTIVE

O:000

1

Operator
Drive Active Status
Display

0002

N9:0

3

Drive Logic Status
ACTUAL FORWARD /
REVERSE DIRECTION

O:000

2

Operator
Drive Actual Forward
Status Display

0003

N9:0

3

Drive Logic Status
ACTUAL FORWARD /
REVERSE DIRECTION

O:000

3

Operator
Drive Actual Reverse
Status Display

0004

N9:0

7

Drive Logic Status
FAULTED

O:000

4

Operator
Drive Fault Status
Display

0005

N9:0

8

Drive Logic Status
AT SPEED

O:000

5

Operator
Drive At Speed
Status Display