Publication 0160-5.18 - June 2003

Using This Manual

P-3

Safety Precautions

Please read the following safety precautions carefully:

!

ATTENTION: Risk of injury or death exists. The
drive contains high voltage capacitors which take time
to discharge after removal of mains supply. Before
installing or removing the DeviceNet Communication
Module, make sure to isolate the mains supply from line
inputs [L1, L2, L3 (R, S, T)]. Wait three minutes for
capacitors to discharge to safe voltage levels. Failure to
do so may result in injury or death.

!

ATTENTION: Risk of injury or equipment damage
exists. Only personnel familiar with DeviceNet devices,
Bulletin 160 SSC drives, and associated machinery
should plan or implement the installation, start-up,
configuration, and subsequent maintenance of the
Communication Module. Failure to comply may result
in injury and/or equipment damage.

!

ATTENTION: Risk of equipment damage exists. This
module contains ESD (Electrostatic Discharge)
sensitive parts that can be damaged if you do not follow
ESD control procedures. Static control precautions are
required when handling this Communication Module.
If you are unfamiliar with static control procedures,
refer to Guarding Against Electrostatic Damage,
Publication 8000-4.5.2.

!

ATTENTION: Risk of injury or equipment damage
exists. When a system is configured for the first time,
there may be unintended or incorrect machine motion.
Disconnect the motor from the machine or process
during initial system testing.

!

ATTENTION: Hazard of equipment damage exists. If
explicit messages are programmed to frequently change
parameter data in the drive, the EEPROM will quickly
exceed its life cycle and cause the drive to malfunction.
Do not create a program that frequently uses explicit
messages to change a parameter in the drive.