Procedures, Procedures -2 – Rockwell Automation 160-DN2 160-DN2 DeviceNet Communication Module FRN 3.xx User Manual

Page 16

Advertising
background image

Publication 0160-5.18 - June 2003

2-2

Quick Start for Experienced Users

Procedures

Step

Refer to . . .

1

Review Attention statements in the Preface.

Preface

2

Check the contents of the shipping box.
Unpack the shipping box, making sure that it contains:

• Bulletin 160 DeviceNet module (Catalog Number 160-DN2)
• 10-pin linear plug with probe holes and jack screws
DeviceNet Communication Module 160-DN2 User Manual

If the contents are incomplete, call your local Allen-Bradley
representative for assistance.

3

Ensure that the drive is correctly installed and wired. (The
Stop Input, TB3-7 and TB3-8, must be jumpered together
to start the drive.)

Publication 160-SSC
User Manual

4

Ensure that the DeviceNet master and network are
installed and functioning by DeviceNet standards.

DeviceNet Cable
System Planning and
Installation Manual
(Publication DN-6.7.2)

5

Remove the Program Keypad Module or
Ready/Fault Indicating Panel from the drive.

Chapter 3

,

Installation and Wiring

6

Set the DeviceNet Module’s node address and baud rate.
Set the DIP Switches at the back of the module. Switches 1
through 6 set the node address; switches 7 and 8 set baud
rate.

Chapter 3

,

Installation and Wiring

7

Install the DeviceNet module on the drive.

Chapter 3

,

Installation and Wiring

8

Wire the DeviceNet connector and plug it into the drive.

Chapter 3

,

Installation and Wiring

9

Power up the drive and the network.

Important: When power-up occurs, the COMM
(communication status) LED flashes green for 1/4 second, red
for 1/4 second, and then goes blank while the Communication
Module finishes its initialization. If the COMM LED goes red,
there is a problem.

Chapter 3

,

Installation and Wiring

,

Chapter 4

,

Modes of Operation

,

and

Chapter 7

,

Troubleshooting

10

Select the appropriate Electronic Data Sheet (EDS) file.
Select the EDS file with the DeviceNet software or hardware
configurator that you are using to configure the Communication
Module (see

Chapter 5

for EDS file descriptions).

Chapter 6

,

Using 160-DN2 with
DeviceNet Scanner

,

and DeviceNet
Software or Hardware
Configurator Manual

11

Configure the Bulletin 160 SSC drive for DeviceNet so that
the drive can accept speed reference and control logic via
the network.
Use configuration software such as RSNetWorx for DeviceNet
or hardware such as DeviceView Hand Held DeviceNet
Configurator.

Chapter 6

,

Using 160-DN2 with
DeviceNet Scanner

12

Configure the DeviceNet Scanner to recognize the Bulletin
160 SSC drive.
Use RSNetWorx for DeviceNet to configure the DeviceNet
Scanner’s “Scan List” to recognize the Bulletin 160 SSC drive.

Chapter 6

,

Using 160-DN2 with
DeviceNet Scanner

Advertising