Parameter 06 – Drive Faults (Drv Faults) *

Parameter 06 is a 16 bit, binary word that represents the drive faults. A “1”
indicates that a fault has occurred. If a “0” is displayed, a fault has not
occurred. Refer to the list below for an explanation of the individual bits.

Bit 15

Bit 0

Parameter Type:

View only in Maintenance level

bit 0

Not Used

bit 1

Drive Overtemperature

bit 2

Power Up Enable

bit 3

Not Used

bit 4

Control Voltage Fault

bit 5

Resolver Loss

bit 6

Not Used

bit 7

Power Fault

bit 8

Bus Overvoltage

bit 9

Not Used

bit 10

External A/D Conversion Fault

bit 11

Internal A/D Conversion Fault

bit 12

Not Used

bit 13

Not Used

bit 14

EEprom Fault

bit 15

Auto Tune Fault

Parameter 07 – Drive Status (Drv Status) *

A 16 bit, binary word represents the drive status. A “1” indicates that a
particular state exists. If a “0” is displayed, that state does not exist. Refer
to the list below for an explanation of the individual bits.

Parameter Type:

View only in Maintenance level

bit 0

Class 1 Fault

bit 1

At Zero Speed

bit 2

At Speed

bit 3

IT Active

bit 4

EEprom Write Enabled

bit 5

Drive State

bit 6

Drive State

bit 7

Drive State

bit 8

At Current Limit.

bit 9

Not Used

bit 10

Not Used

bit 11

Not Used

bit 12

Not Used

bit 13

Not Used

bit 14

Not Used

bit 15

Not Used.