Chapter 6
Programming

6-21

Parameter 201 – Friction Bit (Frictn Bit)

The number of bits surrounding Friction Hysteresis (parameter 200).

Parameter Type:

View/modify in Maintenance level

Minimum Value:

0

Maximum Value:

50

Default Value:

10

Parameter 210 – Analog to Digital Converter Offset (Anlg Vel Offst)

This parameter adds an offset to the A/D converter value to correct for
input A/D offset and user input command D/A output offset.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

–61 mV

Maximum Value:

+61 mV

Default Value:

0 mV

Parameter 211 – Analog Velocity Gain (Anlg Vel Gain)

This parameter determines how the A/D converter value is scaled. It is set
to the number of motor rpm that is to represent 1 volt of input command.

The desired input velocity command voltage to motor rpm scaling is
accomplished with the Analog Velocity Gain parameter (211). The default
setting is 500 rpm/volt. Use the following formula if the maximum motor
speed (rpm) and maximum velocity command (volts) are known.

Maximum Desired Motor RPM

Maximum Velocity Command

RPM

Volts

=

for example:

3000 RPM Maximum

8V DC Maximum Command

375 RPM

Volts

=

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

–790 rpm per volt

Maximum Value:

+790 rpm per volt

Default Value:

+500 rpm per volt

Parameter 212 – Digital to Analog #1 Gain (D/A 1 Gain)

This parameter scales the D/A #1 Command Value (parameter 58) before it
is output to D/A Converter 1.

To change output voltage scaling: Desired Voltage per 1000 rpm x 0.05553.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

gain of –14.6

Maximum Value:

gain of +14.6

Default Value:

gain of +0.067