Rockwell Automation 1391 USER MNL/DIGITAL AC SERVO DR User Manual

Page 50

Advertising
background image

Chapter 6
Programming

6-13

Parameter 49 – Current Feedback Scale (Cur Fdbk Scale) *

The current feedback scaling is displayed based on motor current rating
and drive size (parameters 155 & 3). See Table 6.A.

Parameter Type:

View only in Maintenance level

Minimum Value:

0

Maximum Value:

15

Table 6.A
Typical Current Feedback Scaling

Motor Rated Current

1391-DES15

15.0
14.1
13.1
12.2

11.3
10.3
9.4
8.4

7.5
6.6
5.6
4.7

3.8
2.8
1.9
0.9

1391-DES22

22.5
21.1
19.7
18.3

16.9
15.5
14.0
12.6

11.3
9.8
8.5
7.0

5.7
4.2
2.8
1.4

1391-DES45

45.0
42.2
39.4
36.6

33.8
30.9
28.1
25.3

22.5
19.7
16.9
14.1

11.3
8.4
5.6
2.8

Parameter 49 Value

15
14
13
12

11
10
9
8

7
6
5
4

3
2
1
0

Parameter 50 – Current Feedback Rated (Cur Fdbk Rated) *

This parameter displays the actual motor current scaling based on current
feedback scale and drive size (parameters 49 & 3).

Parameter Type:

View only in all levels

Minimum Value:

Drive size/16

Maximum Value:

Drive size

Parameter 51 – Current Limit *

The real time current limit is displayed by this parameter.

Parameter Type:

View only in all levels

Min/Max Value:

Whichever is less: 200% drive rating, +/– current limit, 3 times motor current,
ext limit or IT limit

Parameter 57 – Analog Velocity Command (Analog Vel Cmd) *

This parameter displays the analog velocity command value.

Parameter Type:

View only in all levels

Minimum Value:

–7000 rpm

Maximum Value:

+7000 rpm

Advertising