Parameter 183 – Velocity Damping Selection (Vel Damp Selct)

This parameter is associated with the auto tune function and specifies the
velocity damping desired by the user. The auto tuning procedure calculates
a new set of Velocity Loop Gains (parameters 168 & 169) and a new
Current Rate Limit (parameter 158) when the user initiates the Auto Tune
Calculate function. Refer to Figure 8.1 for further information.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

0

Maximum Value:

3

Default Value:

0

0

zeta = 0.87

1

zeta = 1.0

2

zeta = 0.7

3

zeta = 1.4

Parameter 184 – Velocity Low Pass Filter Band-
width (Vel Low Pas BW)

Specifies the single pole low pass velocity feedback filter bandwidth. A
value of 30000 disables the filter.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

0 rads/second

Maximum Value:

30000 rads/second

Default Value:

30000 rads/second

Parameter 185 – Lead/Lag Velocity Fdbk. Filter Gain (Lead/Lag Gain)

Specifies the gain of the velocity feedback filter. A value of 1.00 disables
the filter.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

–10.00 (lag)

Maximum Value:

+10.00 (lead)

Default Value:

1.00

Parameter 186 – Lead/Lag Velocity Fdbk. Filter BW. (Lead/Lag BW)

Specifies the bandwidth of the velocity feedback filter.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

0 rads/second

Maximum Value:

2700 rads/second

Default Value:

250 rads/second

Parameter 187 – Auto Tune Velocity (Auto Tune Vel)

This parameter specifies the maximum velocity attained during an auto
tune cycle.

Parameter Type:

View/modify in Modify level and Maintenance level

Minimum Value:

–2000 rpm

Maximum Value:

+2000 rpm

Default Value:

+1000 rpm