Chapter 6
Programming

6-10

Parameter 08 – Auto Tune Status (ATn Status) *

A 16 bit, binary word represents the auto tune status. A “1” indicates that a
particular state exists. If a “0” is displayed, that state does not exist. Refer
to the list below for an explanation of the individual bits.

Parameter Type:

View only in Maintenance level

bit 0

Ready

bit 1

Active

bit 2

Enable Drive

bit 3

Not Used

bit 4

Accel

bit 5

Decel

bit 6

Abort

bit 7

Complete

bit 8

Enable Time Limit

bit 9

Execution Time Limit

bit 10

Accel Fault

bit 11

Decel Fault

bit 12

Gain Calculation Fault

bit 13

Gains Updated

bit 14

Not Used

bit 15

Not Used

Parameter 17 – Velocity Reference Whole (Vel Ref Whole) *

This parameter supplies the whole number part of an internal digital
velocity reference, when internal digital velocity control has been selected
in parameter 132. The data contained in this parameter represents the
whole number of the velocity reference.

Parameter Type:

View/modify in Maintenance level

Minimum Value:

–8000 rpm

Maximum Value:

+8000 rpm

Parameter 18 – Velocity Reference Fraction (Vel Ref Fract) *

The fractional part of an external velocity reference when internal digital
velocity control has been selected in parameter 132 is contained in this
parameter. The data contained represents the low order, fractional part of
the internal digital velocity reference.

Parameter Type:

View/modify in Maintenance level

Minimum Value:

0 rpm

Maximum Value:

65535 rpm

Parameter 19 – Final Velocity Command (Vel Command) *

Parameter 19 indicates the value of the velocity reference into the velocity
PI regulator, after the Velocity Mode Select (parameter 132) and the
Velocity Limiter.

Parameter Type:

View only, all levels

Minimum Value:

–8000 rpm

Maximum Value:

+8000 rpm

Advertising