Local Parameter Programming

1Ć1

. . . . . . . . . . . . . . . . . . . . .

At all Programming and Display Panels, parameters 0Ć50 and 70Ć89

may be viewed (Read) while the drive is running. Eight of these

parameters display realĆtime events (such as present drive speed

and output current) that cannot be changed (Written to). The

remaining parameters may be changed as long as the drive isn't

running. A decimal point displayed in the far right corner indicates

that programming has been selected and that the enter button has

been pressed. Parameter values may be changed when the decimal

point is present. With the exception of Parameter 45 (which is

programmable in 0.01 kHz increments), all Programming and Display

Panels allow all frequency parameters to be programmed in 0.1 Hertz

increments and all time parameters to be programmed in 1 second

increments.

1Ć1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Four pushbuttons on all Programming and Display Panels are used

for both viewing and programming parameters.

1Ć1

. . . . . . . . . . . .

The PR pushbutton is used to switch from the operating display to the

parameter viewing display. Once in the viewing display, the PR

pushbutton is used to increment through the parameters.

1Ć1

. . . . .

The Enter pushbutton is used to switch from viewing to programming

but only when Parameter 0 is displayed, and only if switch SW1 is

set to allow parameter programming. When programming parameters,

the Enter pushbutton is also used to store the displayed value.

1Ć1

.

These buttons are only functional in the programming mode. When

programming parameters, the increment and decrement pushbuttons

are used to scroll up or down to the parameter value to be entered.

Pressing both buttons simultaneously will end programming and

return the drive to the operating display.

1Ć1

. . . . . . . . . . . . . . . . .

After exiting the programming mode, the stop command must be

cycled to reset the drive and confirm that programming is complete.

Failure to follow these instructions will result in an F11 (Operator Error)

fault.

1Ć1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SW1 is a rocker switch only accessible on the chassis mounted Local

Programming and Display Panel. The switch can be accessed only

with the drive cover removed and may be used to disable the Enter

pushbutton and control access to local programming.