Chapter – Rockwell Automation 1336VT AC DRIVE 5-300AMP (2-160KW) PROGRAMMING MANUAL User Manual

Page 79

Advertising
background image

9

Chapter

9-1

Local and Serial Port Parameter Settings

Firmware Version 1.01Ć3.01

Table 9 -- Parameter List for Parameters 0 to 50

Parameters 0 to 50 can be accessed through either the local or serial port.

Local

Programming

Serial

Panel

Port

Parameter Parameter

Min/Max

Min/Max

Factory

Number

Text

Units

Values

Values

Setting

0

PARAMETER MODE

None

0/0

0/0

0

1

OUTPUT VOLTS

Volts

0/575

0/575

0

2

OUTPUT CURRENT

% of Rated Output Current

0/200

0/200

0

3

OUTPUT POWER

% of Rated Output Power

0/200

0/200

0

4

LAST FAULT

Code

0/37

0/37

0

5

FREQUENCY SELECT 1

Code

0/5

0/5

0

6

FREQUENCY SELECT 2

Code

0/5

0/5

0

7

ACCEL TIME 1

Seconds

0/600

0.00/600.00

5

8

DECEL TIME 1

Seconds

0/600

0.00/600.00

5

9

DC BOOST SELECT

Code

0/1

0/12

2

10

STOP SELECT

Code

0/2

0/2

0

11

DECEL FREQUENCY HOLD

Off/On

0/1

0/1

0

12

DC HOLD TIME

Seconds

0/15

0/15

0

13

DC HOLD VOLTS

Volts

0/115

0/115

0

14

AUTO RESTART

Off/On

0/1

0/1

1

15

FACTORY SET -- DO NOT CHANGE None

0/0

0/0

0

16

MINIMUM FREQUENCY

Hertz

0/120

0/120

0

17

BASE FREQUENCY

Hertz

40/120

40/120

60

18

BASE VOLTS

Volts

115/575

115/575

460

19

MAXIMUM FREQUENCY

Hertz

40/250

40/250

60

20

MAXIMUM VOLTS

Volts

115/575

115/575

460

21

LOCAL RUN

Off/On

0/1

0/1

1

22

LOCAL REVERSE

Off/On

0/1

0/1

1

23

LOCAL JOG

Off/On

0/1

0/1

1

24

JOG FREQUENCY

Hertz

.0/120

0.00/120.00

.0

25

ANALOG OUTPUT

Code

0/1

0/1

0

26

PRESET/2ND ACCEL

Code

0/1

0/1

0

27

PRESET FREQUENCY 1

Hertz

.0/250

0.00/250.00

.0

28

PRESET FREQUENCY 2

Hertz

.0/250

0.00/250.00

.0

29

PRESET FREQUENCY 3

Hertz

.0/250

0.00/250.00

.0

Advertising