Step 1 - Identify Your Unit

1329I-5.5 Integrated Drive/Motor — January, 2000

1.1

1329I Standard Unit

The standard unit, shown in Figure 1.1, provides a local display for speed or percent
load, and diagnostic information. A control signal terminal block in the Drive Section
connects to a user-supplied remote operator control station.

Figure 1.1
1329I Standard Unit

Refer to the

Bulletin 1329I DeviceNet Option User Manual

for a description of the Communication LED.

1.1.1 Standard Unit Display Description

The four-character, seven-segment display shows the drive output speed in RPM or
percent load, and displays active fault codes. Speed in RPM is the default display. To
display percent load, see Section 7.4.

If a fault occurs, the unit displays the corresponding fault code. Refer to Chapter 11 for
more information about fault codes and corrective actions.

1.1.2 Standard Unit Reverse LED Description

The REVERSE LED indicates the requested direction of motor rotation:

Motor Section

Drive Section

Display

Reverse LED

Communication LED

LED Status

Definition

OFF

The requested direction of motor rotation is forward.
(The 1329I unit is shipped with the forward direction defined as CCW shaft
rotation as viewed from the motor shaft end.)

ON

The requested direction of motor rotation is reverse.
(The 1329I unit is shipped with the reverse direction defined as CW shaft
rotation as viewed from the motor shaft end.)