Step 7 - Wire the Control Signal Terminal Block

1329I-5.5 Integrated Drive/Motor — January, 2000

7.3

Wiring the Relay Control Output

A single form A relay on the terminal block can be used to indicate the unit is running
(default) or has faulted (user option) based on the setup DIP switch setting. Refer to the
setup DIP switch description in Chapter 8.

Figure 7.6
Relay Control Output Wiring

7.4

Wiring RPM or Percent Load Display

The RPM or Percent Load Display input (control terminal 12) selects the type of
information displayed by the analog output and the built-in display, speed in RPM or
percent load. Wire a switch between control terminals 12 and 13 as shown in Figure 7.7.

Figure 7.7
RPM or Percent Load Display Wiring

7.5

Wiring the Speed Reference

The standard 1329I unit provides two motor speed reference options:

• Seven preset speeds

• An external 0 to 10 VDC or 4 to 20 mA speed reference source

The 1329I unit with local provides three motor speed reference options:

• The local operator controls (using the

keys)

• Seven preset speeds (the

keys are not used)

• An external 0 to 10 VDC or 4 to 20 mA speed reference source (the

keys

are not used)

17
18
19
20

N.O. Relay

Relay Common

Connect to external device
such as PLC input.

11
12
13
14

RPM or Percent Load Display

24V DC

RPM

% Load