Technical Specifications

1329I-5.5 Integrated Drive/Motor — January, 2000

I/O Specifications

Important:

All signals are isolated from the incoming line power.

Analog inputs

0 to 10 V

Input impedance: 50 k

Resolution: 0.11%

4 to 20 mA

Input impedance: 250

Resolution: 0.14%

Analog output

0 to 10 V

Minimum load resistance: 2 k

Resolution: 0.4%

Logic inputs (Stop, Start, Reset, Fwd/Rev, RPM/%Load, Function
Loss, Preset Speed)

24 VDC sourcing inputs

Maximum input voltage: 28.8 VDC

Input current @ 24 VDC: 10 mA

Maximum OFF state voltage: 5 VDC

Minimum ON state voltage: 15 VDC

Relay output (1 form A N.O. contact) Isolated

Maximum current (resistive or inductive): 1 A

Minimum current: 10 mA

Maximum voltage: 28 VDC, 250 VAC

Approvals and Standards Compliance

Approvals:

UL

®

LISTE

D 966X

IND CONT EQ

UL508C

UL

®

LISTE

D 966X

IND CONT EQ

C

CSA 22.2

EMC Directive 89/336

LV:

EN 50178, EN 60204

EMC: EN 61800-3, EN 50081-1, EN 50082-2