Rockwell Automation 1329I Integrated AC Drive/Motor, Series B FRN 3.X User Manual
Page 66
A-2
Technical Specifications
1329I-5.5 Integrated Drive/Motor — January, 2000
Maximum continuous output current:
Maximum output current:
Important:
Maximum current ratings above are for the CT rating. When VT is
selected, the maximum output current will be limited to 110%.
Output frequency:
• 0 to 120 Hz
Carrier frequency:
• 8 kHz
Input Voltage
Unit HP
Output Current
(Motor Rated Amps)
460 VAC
1 HP
1.7 A
460 VAC
2 HP
3.2A
460 VAC
3 HP
4.5 A
460 VAC
5 HP
6.9 A
230 VAC
1 HP
3.4 A
230 VAC
2 HP
6.4 A
230 VAC, 1-phase
1 HP
3.4 A
230 VAC, 1-phase
2 HP
6.4 A
115 VAC
1 HP
6.8 A
Input Voltage
Unit HP
Maximum Output Current
(150% Rated Amps)
460 VAC
1 HP
2.55 A
460 VAC
2 HP
4.8 A
460 VAC
3 HP
6.75 A
460 VAC
5 HP
10.35 A
230 VAC
1 HP
5.1 A
230 VAC
2 HP
9.6 A
230 VAC, 1-phase
1 HP
5.1 A
230 VAC, 1-phase
2 HP
9.6 A
115 VAC
1 HP
10.2 A