Checklist-2

Installation Checklist

1329I-5.5 Integrated Drive/Motor — January, 2000

Installation Overview

PE

DC Bus (Do Not

Wire)

DBR (Do Not

Wire)

A

C

Inputs

A

C

Input P

o

wer Connections

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20

10

V

olt Ref

erence

0 – 10V DC Speed Ref

erence Input

4 – 20 mA Speed Ref

erence Input

Common

0 – 10

V

olt Output

Common

Speed Preset 2

Speed Preset 1

Speed Preset 0

F

orw

ard/Re

verse

24 V

olt

DC

RPM/P

ercent Load Displa

y

Reset

Star

t

Stop

24

V

olt DC Common

N.O

. Rela

y

Rela

y Common

24 V

olt

DC

Function Loss

-+

RPM

% Load

OFF

ON

Enab

led

Te

rminal Bloc

k

F

aulted

Enab

led

Constant

Ramp-to-Rest

Disab

led

F

rom T

e

rminal

Bloc

k

F

rom T

e

rminal

Bloc

k

F

rom EEPR

OM Memor

y

Run On P

o

w

er Up

Speed Ref

erence

Rela

y Control Output

A

uto Restar

t

Torque Cur

ve

Stop

Re

verse

Minim

um Speed

Star

t Mode

P

a

rameter Mode

Disab

led

Oper

ator Controls

Running

Disab

led

V

a

riab

le

Coast-to-Rest

Enab

led

0 Hz

F

rom Oper

ator Controls

F

rom Setup Switches

Setup DIP Switc

h (SW3)

Switches 2 and 9 apply to local oper

ator control units only

.

Switch 10 applies to the De

viceNet Comm

unication option only

.

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20

10

V

olt Ref

erence

0 – 10V DC Speed Ref

erence Input

4 – 20 mA Speed Ref

erence Input

Common

0 – 10

V

olt Output

Common

Speed Preset 2

Speed Preset 1

Speed Preset 0

F

orw

ard/Re

verse

24 V

olt

DC

RPM/P

ercent Load Displa

y

Reset

Star

t

Stop

24

V

olt DC Common

N.O

. Rela

y

Rela

y Common

24 V

olt

DC

Function Loss

-+

+10V DC

5K

RPM

Fwd

Re

v

% Load

13

16 17

Maintained 2-Wire Star

t.

Momentar

y 3-Wire Star

t.

0 = 1 Second Accel/5 Sec Decel

1 = 5 Seconds (Def

ault)

2 = 10 Seconds

3 = 15 Seconds

4 = 20 Seconds

5 = 30 Seconds

6 = 60 Seconds

7 = 90 Seconds

0 = 1500 RPM (50 Hz)

1 = 1800 RPM (60 Hz) Def

ault

2 = 2100 RPM (70 Hz)

3 = 2400 RPM (80 Hz)

4 = 2700 RPM (90 Hz)

5 = 3000 RPM (100 Hz)

6 = 3300 RPM (110 Hz)

7 = 3600 RPM (120 Hz)

Max Speed Switc

h (SW2)

Accel/Decel Switc

h (SW1)

Contr

ol Signal

T

erminal Bloc

k

Selector

s and Connector

s

Standar

d Unit

Local Operator Contr

ol Unit

Connect to e

xter

nal de

vice

.

The jumper betw

een ter

minals 7 and 11 m

ust be remo

ved when

wir

ing the Function Loss input.

See Section 7.1 f

or more inf

or

mation.

The jumper betw

een ter

minals 13 and 17 m

ust be remo

ved when

wir

ing the Stop input.

See Section 7.6 f

or more inf

or

mation.

An e

xter

nal 0 to 10 v

olt or 4 to 20 mA speed ref

erence source can

be connected.

See Section 7.5.3 of the User Man

ual f

or more inf

or

mation.

= N.O

. Momentar

y Contact

= N.C

. Momentar

y Contact

= Maintained Contact - Closed

= Maintained Contact - Open

Ground / Protectiv

e Ear

th

= Def

ault Setting (OFF P

osition)

Connect to e

xter

nal de

vice

.

DC+

DC-

DBR

T/L3

S/L2

R/L1