Appendix A Tag Definitions

Analog Only

This table describes the input tags available in the Analog Only data format.

Ch5Config

AB:1756_OF8H_ChConfig_Struct:C:0

Ch6Config

AB:1756_OF8H_ChConfig_Struct:C:0

Ch7Config

AB:1756_OF8H_ChConfig_Struct:C:0

PassthroughHandleTime
out

INT

Decimal

Seconds to keep a reply to a HART pass-through service request before discarding.
15 seconds recommended.

PassthroughFreq_14

BOOL

Decimal

Selects the policy for sending HART pass-through messages. See

Pass-through Setting, Ratio, and

Priority on page 101

PassthroughFreq_15

BOOL

Decimal

Table 66 - Configuration (AB:1756_OF8H:C:0)

Member Name

Type

Style

Description

Table 67 - Analog Only (AB:1756_OF8H_Analog:I:0)

Member Name

Type

Style

Description

ChannelFaults
(bits 9…15 unused)

INT

Binary

ChxFault

BOOL

Decimal

ChannelFaults.x, Indicates communication fault or fault condition from ChXStatus.

LoopOutputFault

BOOL

Decimal

ChannelFaults.8, This is a hardware fault where the module has detected that the power supply to the
isolated (analog) side of the board has failed (no power). It does not roll into any other bits. The
OK status indicator is set to solid red.

HARTFaults

SINT

Binary

ChxHARTFault

BOOL

Decimal

HARTFault.x
Indicates a problem with HART data from the field device on Channel x. Examples are HART not
enabled, HART device not connected, HART communication failure due to noise.
The following field device status conditions also cause this to be set: Device Malfunction,
PV Out of Limits, Loop Current Saturated, and Loop Current Fixed.

ModuleFaults

SINT

Binary

CalFault

BOOL

Decimal

ModuleFaults.1, 1756-IF8H module calibration failed.

Calibrating

BOOL

Decimal

ModuleStatus.2, Calibration in progress.

AnalogGroupFault

BOOL

Decimal

ModuleFaults.7, Indicates a fault has occurred on any channel (any of ChannelFaults).

Ch0Status

SINT

Binary

Indicates various alarms on the analog signal. Also sets Ch0Fault for Overrange, Underrange,
and CalFault.

Ch0HLimitAlarm

BOOL

Decimal

Ch0Status:0 The analog output signal is being limited by the Ch0Config.HighLimit value.If
Ch0Config.LimitAlarmLatch is 1, alarm is retained until explicitly reset.

Ch0LLimitAlarm

BOOL

Decimal

Ch0Status:1 The analog output signal is being limited by the Ch0Config.LowLimit value.If
Ch0Config.LimitAlarmLatch is 1, alarm is retained until explicitly reset.

Ch0RampAlarm

BOOL

Decimal

Ch0Status:2 Rate of change in Ch0Data exceeds Ch0Config.MaxRampRate. Rate of change is
determined by the change in Ch0Data divided by the RPI period. Thus if a step change in Ch0 cannot
be reached via the configured MaxRampRate within one RPI, then Ch0RampAlarm is set to 1. If
Ch0Config.RampAlarmLatch is 1, then Ch0RampAlarm remains set until explicitly reset using CIP
message even if the condition returns to normal. The CIP message can be sent via MSG instruction in
the Logix controller or from the the RSLogix 5000 Module Properties Limit dialog box.

Ch0InHold

BOOL

Decimal

Ch0Status:3 Channel holding its last output value, waiting for controller to match the value, indicating
that bumpless initialization of the control loop is complete.

Ch0CalFault

BOOL

Decimal

Ch0Status:4 Fault during calibration of channel 0.