Publication 1734-UM015A-EN-E - November 2009

Configuring POINT I/O and ArmorPOINT I/O DeviceLogix modules using RSNetworx for DeviceNet 57

The 1734-IE4C has an input message that looks like this:

To use the analog data from channel 2, click

to place an analog bit input

on the function block sheet in the DeviceLogix editor.

Channel 2 is mapped to Word 2. Select this as shown below. For help on
mappings, see

Appendix A

.

To use the Over-range bit of channel 1, you can use "bit input" I/O tag and
select Peer#1, byte 9, bit 7.

Again, it is best to use the Peer Connection Status bits (Peer#1 Data Valid and
Peer#1 Exists) to validate the data before using it.

Default Data Map for the 1734-IE4C Analog Input Module
Message size: 12 bytes

Byte

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

Produces
(scanner
Rx)

Input Channel 0 High Byte

Input Channel 0 Low Byte

Input Channel 1 High Byte

Input Channel 1 Low Byte

Input Channel 2 High Byte

Input Channel 2 Low Byte

Input Channel 3 High Byte

Input Channel 3 Low Byte

Status Byte for Channel 1

Status Byte for Channel 0

O
R

U
R

H
H
A

LL
A

H
A

L
A

C
M

CF O

R

U
R

H
H
A

LL
A

H
A

L
A

C
M

CF

Status Byte for Channel 3

Status Byte for Channel 2

O
R

U
R

H
H
A

LL
A

H
A

L
A

C
M

CF O

R

U
R

H
H
A

LL
A

H
A

L
A

C
M

CF