C h a p t e r 1 – G e t t i n g S t a r t e d

Page 31

Baseline 3200

Step 1: Search for biCoders

Valve biCoder assignment is accomplished in
the biCoder Menu dial position.

Turn the dial to the biCoder Menu, then press
ENTR to Search for biCoders.

Like all menus on the 3200, you can look at
the on-screen help for instructions.

The Search may take several minutes to complete. You
will see a status screen like the one shown here while
the search is in progress.

Press CLR to cancel a search in progress.

Step 2: Assign biCoder(s) to Zones

Use the +/- keys to select any unassigned
biCoder serial number.

Use the NEXT/PREV keys to select an
available Zone Number.

Press ENTR to Assign the selected biCoder to
that Zone Number.

Master Valves MV1-MV4 are assigned this
same way, and can be assigned to any single
or two valve biCoder.

CLEAR Function – clear a previous zone
number assignment.

To clear a biCoder serial number previously
assigned to a Zone Number, use NEXT/PREV
to highlight that Zone Number, then use the
+/- keys to select “Clear”, then press ENTR.

In the Zone Number list, Zones that have
been set to be Primary Zones will have a “P”
next to them.