C h a p t e r 5 – R e f e r e n c e

Page 72
Baseline 3200

OFF

This is the shutdown dial position for the
controller. With the dial in this position the
controller will not water. Here are the other conditions it enforces:

It will continue to take biSensor moisture readings every ten minutes and log them
into flash memory.

It will power down the two-wire (even if it has been set to always be powered up).

It will monitor and record flow rate and water usage and will shut down master valves
on high flow, unscheduled flow, or budget exceeded if they are enabled. Flow
readings will be taken at the same time as moisture readings

The best high flow shutdown is provided with a Flow+NOMV device that is
powered externally from a separate 24 VAC power supply. This device can
monitor flow rate 24x7, even with the controller in OFF (or powered down)
and can shut down the NOMV if the high flow limit is exceeded.