C h a p t e r 5 – R e f e r e n c e

Page 57

Baseline 3200

conditions then use the + or – keys to scroll between each of them. Each pause
condition can be cleared by pressing the CLR key, however, if the cause of the pause
condition has not be changed, the pause state will return. As seen in this example of
a water window pause, it cannot really be cleared with the CLR key. This will clear
itself when the water window has expired, or when the water window programming
is changed. The following is a list of pause conditions:

BL-Commander
(handheld radio)

All programs will be paused while running a zone using
the remote handheld radio – all programs will resume
when the zone is shut off.

Use CLR to terminate the manual zone.

Automatically cleared with zone is done.

BaseManager
(central control
software)

Normal operation will continue while the controller is
accessed by BaseManager.

Use CLR to terminate the BaseManager connection.

Automatically cleared with BaseManager logs off.

Event Day

An event day will stop all watering and keep programs
from starting.

Use CLR to terminate the event day.

Automatically cleared when the event day ends.

Flow Devices

A high-flow shutdown or an over-budget shutdown will
stop watering from using the specific flow device.

Use CLR to reset a high flow shutdown condition.

A CLR will not clear an over budget condition – change
the budget or wait until next month.

Not automatically cleared – user must clear this.

Flow Switch

An open jumper or flow switch will stop all watering
and keep all programs from starting.

A CLR will not reset this condition. Replace the jumper
or reset the flow switch hardware.

Not automatically cleared – user must clear this.

Low
Temperature

A temperature below 38 F. will pause all watering.

A CLR will not reset this condition and you must wait
until the temperature rises.

Automatically cleared with higher temperatures.

Pause biCoder

A pause bicoder will pause watering on specific
programs.

A CLR will reset the pause condition before the delay
time has elapsed.

Automatically cleared at end of delay time.