Baseline Systems BaseStation 3200 User Manual

Page 60

Advertising
background image

C h a p t e r 5 – R e f e r e n c e

Page 58
Baseline 3200

Pause Switch

An open jumper or wired switch will pause all watering
on the controller.

A CLR will not reset the pause condition until the
jumper or switch has closed the circuit, then CLR will
reset the pause condition before the delay time has
elapsed.

Automatically cleared at end of delay time.

Rain Switch

An open jumper or wired rain sensor that is wet (open)
will stop all watering, and will stop all programs from
starting.

A CLR will not reset the pause condition until the
jumper or rain sensor has closed (dried out).

Automatically cleared by switch or rain sensor closure.

Rain/OFF days

Setting a rain/off value for the number of days will stop
all watering for that period of time.

A CLR will reset the delay days to zero, clearing the
pause condition.

Automatically cleared when delay days are over.

Water Window

A water window (white squares) will pause a program.

A CLR will not reset the water window pause condition
– you must wait or change the water window
programming.

Automatically cleared when the water window expires
(time advances to a blue square).

Press the NEXT key to move to the next status screen.

Message Screen – this screen lists the
messages that have been caused by
alerts and other events which are
notified to the user. This screen can
be seen only when there is an active
message (see the example to the
right). If there are multiple messages,
they can be viewed individually by
pressing the + key to advance
through the list. Note the details of
the message as well as suggestions to
correct the issue and the time and
date of the alert – this reflects when this alert first happened. The CLR key can be
pressed to clear the message once it has been read and the appropriate action has
been taken. There are dozens of possible messages. The more common ones are
listed below.

biSensor Disabled: error rate too high

Water used exceeded monthly budget

Calibrate Failure: no moisture change

Advertising