C h a p t e r 5 – R e f e r e n c e

Page 60
Baseline 3200

Primary

This zone type is used for the first zone in a zone scheduling
group. Making changes to a primary zone will automatically
make corresponding changes in all linked zones.

A biSensor can only be assigned to primary zones.

Linked

A linked zone will follow the watering and programming of the
primary zone that it is linked to. If zone 2 is linked to primary
zone 1, then it will follow zone 1.

A linked zone must have a higher number than the primary
zone it is linked with.

Water Time – the zone water time can be set from 1 minute to 23 hours 30 minutes.
Linked zones are programmed as a tracking ratio or percent of the primary zone. For
a primary zone set to 60 minutes, a linked zone that is programmed at 150% would
have a water time of 90 minutes. Linked zone ratios range from 30% to 1000%.
Changing the primary zone to a new water time will adjust linked zones by their
tracking ratios.

Program – there are twenty programs (A to T) for ultimate flexibility. A zone may be
assigned to any program. Linked zones are automatically assigned to the program of
their primary zone and cannot be changed independently.

Start Times

There are two sections of the Start Times dial
position: start times and water windows.

Program Start Times

Each active program must have at least one start time. Refer to the sample screen to the right.
If a program has no start time then it is disabled and will not run. Programs can have from one to
eight start times. Start times are set in 15 minute increments.

To set a new start time, highlight an empty box on the screen using NEXT/PREV and press the +
or – key. Use the + or – key to change the start time to that desired. A start time may be deleted
by pressing the CLR key with the start time highlighted.

Press ENTR to quickly move to the next program.