C h a p t e r 5 – R e f e r e n c e

Page 70
Baseline 3200

Self-Test – Verify and Repair All

This function will verify communication with each of the devices on the two-wire. It does not
check the valve current nor does it check biSensor readings. If it finds a problem, it will attempt
to repair in the following repair order:

Repair valve biCoder to zone number assignments

Repair biSensor addressing

Repair pause device addressing

Repair air temperature sensor addressing

If you are troubleshooting two-wire problems (damaged and repaired), it is
a good idea to do a backup before doing search operations. Call Baseline
support for help and guidelines, 866-294-5847.

Manual Run Program

This dial position has three different operations
that can be performed. The first menu item can
be toggled between the program start/stop and
next start date by using the + or – keys. Then use the NEXT/PREV keys to highlight the desired
program. Use the + or – key to then change the value for the highlighted program.

1.

A program that is stopped can be started (set to running). It will then run a full cycle
when the dial is turned to Auto/Run.

2.

A program that is running can be
terminated (set to stopped).

3.

A program that is using a Historical ET
Calendar can have its next run date
set. Programs that do not use this
mode have a fixed schedule and are
modified in the Day Intervals dial
position.

Advertising