C3-1006, C3-1007, C3-1008 – Dell POWEREDGE M1000E User Manual

Page 217

Advertising
background image

Fabric OS Message Reference

195

53-1002749-01

C3-1006

5

C3-1006

Message

S<slot number>,C<chip index>: Various non-critical hardware errors were observed:
fault1:0x<fault1_cnt>, fault2:0x<fault2_cnt> thresh1:0x<threshold_used>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that some errors were found in hardware that may or may not impact the data traffic.

Recommended

Action

No action is required. Usually these errors are transient.

C3-1007

Message

S<slot number>,P<port number>(<blade port number>): best effort QoS will be turned
off at next port state change as it is not supported under this configuration.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that quality of service (QoS) will be turned off automatically at the next port state change
because best effort QoS is no longer supported on 4 Gbps or 8 Gbps platform long distance ports.

Recommended

Action

No action is required.

C3-1008

Message

S<slot number>,P<port number>(<blade port number>): QoS overwrites
portcfglongdistance vc_translation_link_init. ARB will be used on the link.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that quality of service (QoS) has overwritten the fill word IDLE used on the long distance links.
Arbitrated loop (ARB) will be used on the link.

Recommended

Action

No action is required.