SEC-1333

5

SEC-1333

Message

<Name of command> command failed. There are VF enabled switch(s) in fabric. <List
of databases rejecting distribution> db(s) distribution is blocked.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates there was an attempt to distribute PWD or IPFILTER databases from the fabric to a switch that
is VF-enabled

Recommended

Action

Disable VF on all the switches that have VF-enabled if PWD or IPFILTER databases need to be
distributed.

SEC-1334

Message

SSH Daemon is restarted.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the Secure Shell (SSH) daemon was not running and it was restarted.

Recommended

Action

No action is required.

SEC-1335

Message

Strict <Policy Name> policy is conflicting with domain <Domain Number>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the policy is conflicting with the domain.

Recommended

Action

No action is required. The domain is denied by disallowing all its E_Ports connected to the fabric. If the
domain should be allowed to merge with the fabric, then resolve the issue by making the conflicting
policies the same.