HAM-1006

5

HAM-1006

Message

EMAC controller for Active CP is BAD.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the local Ethernet Media Access Controller (EMAC) on the active CP has been marked
BAD as determined by the diagnostic test run by the high availability manager (HAM) module.

Recommended

Action

The standby CP will take over and reset the active CP. The system will be non-redundant because the
standby CP becomes the active CP.

HAM-1007

Message

Need to reboot the system for recovery, reason: <reason name>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the switch in current condition needs to be restarted to achieve a reliable recovery. The
reasons can be one of the following:

The standby CP was not ready when failover occurred.

The failover occurred when the last logical switch (LS) transaction was incomplete.

The switch failed when timeout occurred at certain stage.

The cold or warm recovery has failed.

Recommended

Action

If auto-reboot is enabled, the switch will automatically restart. Otherwise, execute the reboot command
to manually restart the switch.

HAM-1008

Message

Rebooting the system for recovery - auto-reboot is enabled.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the recovery by auto-reboot is enabled, and therefore the switch automatically restarts.
This message is displayed if the event logged in HAM-1007 has occurred and auto-reboot is enabled.

Recommended

Action

Wait until the switch is up to perform any operations.