Fabric OS Message Reference

53-1002749-01

TRCE-1007

5

TRCE-1007

Message

Notification of this CP has failed. Parameters temporarily out of synch with other
CP.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the active control processor (CP) is unable to alert the standby CP of a change in trace
status. This message is only applicable to bladed switches.

Recommended

Action

This message is often transitory. Wait a few minutes and try the command again.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

TRCE-1008

Message

Unable to load trace parameters.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the active control processor (CP) is unable to read the stored trace parameters.

Recommended

Action

Reboot the CP (dual-CP system) or restart the switch.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

TRCE-1009

Message

Unable to alert active CP that a dump has occurred.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) is unable to communicate trace information to active
CP. This message is only applicable to bladed switches.

Recommended

Action

Execute the haShow command to verify that the current CP is standby and the other CP is active.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.