560

Fabric OS Message Reference

53-1002749-01

HIL-1508

5

HIL-1508

Message

Fan faulty warning time expired. System preparing for shutdown.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that temperatures in the system have remained above the critical threshold too long.

Recommended

Action

To avoid causing damage to the switch, the system shuts down automatically. To help prevent future
problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within the operational range
of your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.

HIL-1509

Message

High temperature (<measured temperature> C). Warning time expired. System
preparing for shutdown.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that temperatures in the system have risen above the critical threshold.

Recommended

Action

To avoid causing damage to the switch, the system shuts down automatically. To help prevent future
problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within the operational range
of your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.

HIL-1510

Message

Current temperature (<measured temperature> C) is below shutdown threshold. System
shutdown canceled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that temperatures in the system have dropped below the critical threshold; the system can
continue operation.

Recommended

Action

To help prevent future problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within the operational range
of your switch. Refer to the hardware reference manual for your switch for the operational temperature
range.