Mcast_ss-1014, Mcast_ss-1015, Mcast_ss-1016 – Dell POWEREDGE M1000E User Manual

Page 630

Advertising
background image

608

Fabric OS Message Reference

53-1002749-01

MCAST_SS-1014

5

Recommended

Action

Restart the MCAST_SS daemon.

MCAST_SS-1014

Message

Snooping DB error: <op> (<reason>) MAC Not found - VLAN <vid> MAC-addr <mac
address>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the media access control (MAC) address lookup for the specified VLAN has failed.

Recommended

Action

Restart the MCAST_SS daemon.

MCAST_SS-1015

Message

HSL error: <op> (<reason>) failed for message <message> VLAN <vid> MAC <mac
address> mgid <mgid> CPU <cpu>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified hardware subsystem layer (HSL) related operation has failed.

Recommended

Action

Restart the MCAST_SS daemon.

MCAST_SS-1016

Message

Message error: <op> (<reason>) <length>(<length1>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the length of the message received from the driver is invalid.

Recommended

Action

Restart the MCAST_SS daemon.