SEC-1183

5

Recommended

Action

No action is required.

SEC-1183

Message

Policy to binary conversion error: Port <port number> is out range.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a security database conversion has failed because of an invalid value.

Recommended

Action

Retry the command with a valid value.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

SEC-1184

Message

<Security server (RADIUS/LDAP/TACACS+)> configuration change, action <action>,
server ID <server name>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the specified action is applied to the specified remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) server configuration. The possible actions are ADD, REMOVE, CHANGE,
and MOVE.

Recommended

Action

No action is required.

SEC-1185

Message

<action> switch DB.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the switch database was enabled or disabled as the secondary authentication, accounting, and
authorization (AAA) mechanism when the remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) is the primary AAA mechanism.

Recommended

Action

No action is required.