Fabric OS Message Reference

861

53-1002749-01

TRCE-1010

5

TRCE-1010

Message

Traced fails to start.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the trace daemon (traced), which is used for transferring trace files has failed to start. The
trace capability within the switch is unaffected. The system automatically restarts the traced facility after a
brief delay.

Recommended

Action

Reboot the CP (dual-CP system) or restart the switch.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

TRCE-1011

Message

Trace dump manually transferred to target ' <optional string to indicate which
slot the trace dump is transferred> ': <result>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the trace dump files were manually transferred to the specified slot.

Recommended

Action

No action is required.

TRCE-1012

Message

The system was unable to retrieve trace information from slot <Slot number of the
blade on which the attempt was made>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the system was unable to retrieve trace information from the specified slot because there is
no communication between the main system and the specified slot.

Recommended

Action

Make sure the blade is enabled and retry the command. If the blade is already enabled, execute the
supportSave command and contact your switch service provider.