Ficn-1077, Ficn-1078 – Dell POWEREDGE M1000E User Manual

Page 421

Advertising
background image

Fabric OS Message Reference

399

53-1002749-01

FICN-1077

5

FICN-1077

Message

DevTapeEgr:Unloaded:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>:states=0x<4 prior emulation
states><previous emulation state><current emulation state>:cmds=0x<last 4
commands received from the channel for this device>:status=0x<last 4 status values
received from the channel for this device>:flags=0x<tape report bit flags
(0x80-Tape Loaded,0x40-WriteEmul,0x20-RdBlkEmul,0x10-RdCpEmul)>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a Rewind and Unload I/O has been processed from a remotely connected Logical Partition
(LPAR), which indicates that a tape should be unloaded on a device.

Recommended

Action

No action is required.

FICN-1078

Message

DevTapeEgr:WriteReport:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>:Emuls=0x<the number of idle
state to non-idle state transitions while this tape was loaded>:Cmds=0x<the number
of emulated host write commands processed while this tape was
loaded>:Chains=0x<the number of emulated host chains processed while this tape was
loaded>:MBytes=<the number of emulated write Kilobytes processed while this tape
was loaded>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a Rewind and Unload I/O has been processed from a remotely connected Logical Partition
(LPAR) and Write Tape Pipelining was performed on the currently loaded tape.

Recommended

Action

No action is required.

Advertising