Fabric OS Message Reference

255

53-1002749-01

CVLC-1031

5

CVLC-1031

Message

Primary LUN is restored from mirror LUN. LUN in read-only mode. Container: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a re-keyed primary LUN may have been restored from a mirror LUN without synchronizing.

Recommended

Action

Perform the following steps.

1. Create a new primary LUN.

2. Add the new primary LUN to its container with the

-newLUN

option.

3. Using host-based migration application, copy data from the old to the new primary LUN.

CVLC-1032

Message

Secondary metadata for LUN has been restored. Container: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the host I/Os to secondary metadata region.

Recommended

Action

No action is required.

CVLC-1033

Message

Rebalance completed for EE: <EE name>. Device login in progress.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a rebalance operation was performed.

Recommended

Action

No action is required.