background image

Fabric OS Message Reference

749

53-1002749-01

SEC-1330

5

SEC-1330

Message

<Name of command> command failed -<List of databases rejecting distribution> db(s)
are coming from a non-Primary switch.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an attempt was made to distribute databases either from a backup fabric configuration server
(FCS) switch or a non-FCS switch.

Recommended

Action

Verify the distribution is initiated by the FCS switch. Use the secPolicyShow command to verify and
correct the configuration if necessary.

SEC-1331

Message

Attempt to enable secure mode failed. Reason: <Reason>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the secModeEnable command failed on the fabric because default IP filter policies are not
active on the switch, or an active transaction exists on IP filter policies.

Recommended

Action

Verify the security event was planned.

If the security event was planned, run the ipfilter --activate default_ipv4 command or the ipfilter
--activate default_ipv6
command to activate default IP filter policies. Use the ipfilter --save or ipfilter
--transabort
commands to save or abort the active transaction on IP filter policies. Then retry the
secModeEnable command.

SEC-1332

Message

Fabric wide policy is conflicting as <Policy Name> is present in the fabric wide
policy and 5.3 or 5.2 switches present in the fabric.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the fabric-wide policy is conflicting.

Recommended

Action

Remove either the FCS from the fabric-wide policy, or remove Fabric OS v5.3 or Fabric OS v5.2 switches
from the fabric, or set the fabric-wide mode for FCS as strict.