Regulatory Mode Functions

The function of the front panel

TARE

and

ZERO

keys depends on the value specified for the REGULAT parameter

on the FEATURE menu. Table 11-5 describes the function of these keys for the NTEP, CANADA, OIML, and
NONE regulatory modes.

TARE

and

ZERO

key functions are configurable when the REGULAT mode is set to

INDUST (see Table 11-6 on page 101).

Table 11-5. TARE and ZERO Key Functions for REGULAT Parameter Settings

REGULAT

Parameter Value

Weight on Scale

Tare in System

Front Panel Key Function

TARE

ZERO

NTEP

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

TARE

CANADA

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

no action

OIML

zero or negative

no

no action

ZERO

yes

CLEAR TARE

ZERO and CLEAR TARE

positive

no

TARE

ZERO

yes

TARE

ZERO and CLEAR TARE if

weight is within ZRANGE.

No action if weight is outside of

ZRANGE

NONE

zero or negative

no

TARE

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

CLEAR TARE

Table 11-6 lists the subparameters available when configuring a scale using INDUST mode. The table includes the
default values of the INDUST subparameters and the effective (not configurable) values used by the NTEP,
CANADA, OIML, and NONE regulatory modes.

REGULAT / INDUST Parameter

REGULAT Mode

Parameter Name

Text Prompt

INDUST

NTEP

CANADA

OIML

NONE

SNPSHOT

Display or Scale weight source

DISPLAY

DISPLAY

DISPLAY

DISPLAY

SCALE

HTARE

Allow tare in display hold

NO

NO

NO

NO

YES

ZTARE

Remove tare on ZERO

NO

NO

NO

YES

NO

KTARE

Always allow keyed tare

YES

YES

NO

YES

YES

MTARE

Multiple tare action

REPLACE

REPLACE

NOTHING

REPLACE

REMOVE

NTARE

Allow negative tare

NO

NO

NO

NO

YES

CTARE

Allow CLEAR key to clear tare/
accumulator

YES

YES

NO

NO

YES

PRTMOT

Allow print while in motion

NO

NO

NO

NO

YES

PRTPT

Add PT to keyed tare print

NO

NO

YES

YES

NO

PRTHLD

Print during display hold

NO

NO

NO

NO

YES

HLDWGH

Allow weigh during display hold

NO

NO

NO

NO

YES

Table 11-6. REGULAT / INDUST Mode Parameters, Comparison with Effective Values of Other Modes