Figure 3-10. SCALES Menu, CALIBR Submenu

Table 3-5. SCALES Menu, CALIBR Submenu Parameters

SCALES Menu, CALIBR Submenu

Parameter

Choices

Description

Level 4, CALIBR submenu

WZERO

Press ENTER to display and edit the zero calibration A/D count or millivolts value.

WVAL

Press ENTER to display and edit the test weight value.

Note

If unable to change value using keypad, use the following method to enter new
value:
To enter new value use the up/down keys to change the first digit to desired
number. Then use the key pad to enter the rest of the numbers.

Example: To enter 25000 change the first number using up/down arrows to 2. Then use the keypad and
enter 5000. The result will be 25000.

WSPAN

Press ENTER to display and edit the span calibration A/D count or millivolts value.

WLIN

POINT 1 —
POINT 5

Press ENTER to display and edit test weight and calibration values for up to five linearization points.

Perform linear calibration only after WZERO and WSPAN have been set.

REZERO

Press ENTER to remove an offset value from the zero and span calibrations.

Note

Use this parameter only after WZERO and WSPAN have been set. See
Section 4.2 on page 47
for more information about using this parameter.

UNITS

LB
KG
G
OZ
TN
T
GR
troyoz
troylb
LT
CUSTOM
NONE
OFF

Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; G=gram; OZ=ounce; TN=short ton; T=metric ton; GR=grain; troyoz=troy
ounce; troylb=troy pound; LT=long ton.

WZERO

WVAL

WSPAN

WLIN

REZERO

POINT 4

POINT 5

POINT 1

POINT 2

POINT 3

VISIBLE

GRADS

FORMAT

CALIBR

SCALES Menu, FORMAT Submenu, SPLIT

OFF

Parameter

Choices

Description

Table 3-4. SCALES Menu, FORMAT Submenu Parameters, SPLIT

OFF (Continued)