Table 3-9. DIG I/O Menu Parameters

DIG I/O Menu

Parameter

Choices

Description

Level 2 submenus

SLOTx

BIT y

Lists available digital I/O slots.

Level 3 submenus

BIT y

OFF
INPUT
OUTPUT
ZERO
NT/GRS
TARE
UNITS
PRINT
ACCUM
SETPTS
TIMDATE
ESC
CLEAR
DSPTAR
KEY0—KEY9
KEYDP
ENTER
NAVUP
NAVDN
NAVLFT
NAVRGT
KBDLOC
HOLD
*BATRUN
*BATSTRT
*BATPAUS
*BATRESET
*BATSTOP
CLRCN
GROSS
NET
PRIM
SEC
TER
CLRTAR
CLRACC

Specifies the function of the digital I/O bit.

• OFF indicates that the bit is not configured.

• INPUT assigns the bit as a digital input.

• OUTPUT assigns the bit as a digital output.

• ZERO, NT/GRS (net/gross mode toggle), TARE, UNITS, and PRINT provide the same

functions as the five major front panel keys.

• ACCUM adds the current scale weight to the accumulator, if the scale accumulator is

enabled.

• SETPTS and TIMDATE provide the same function as the Setpoint and Time/Date softkeys.

• TIMDATE provides the same function as the Time/Date softkey.

• ESC provides a function equivalent to the Cancel softkey.

• CLEAR simulates pressing the front panel CLR key.

• DSPTAR displays the current tare; equivalent to pressing the Display Tare softkey.

• KEY0—KEY9 and KEYDP (decimal point) simulate pressing keys on the numeric keypad.

• ENTER simulates pressing the front panel ENTER key.

• NAVUP, NAVDN, NAVLFT, and NAVRGT simulate pressing the navigation keys.

• KBDLOC locks the keyboard (indicator front panel) when held low.

• HOLD holds the current display. Releasing this input clears the running average filter.

• BATRUN allows a batch routine to be started and run. With BATRUN active (low), the

BATSTRT input starts the batch; if BATRUN is inactive (high), BATSTRT resets the batch.

• BATSTRT starts or resets a batch routine, depending on the state of the BATRUN input.

• BATPAUS pauses a batch routine when held low.

• BATRESET stops the batch sequence and resets to the first batch step.

• BATSTOP stops the batch routine.

• CLRCN resets the consecutive number to the value specified on the CONSTUP parameter

(FEATURE menu).

• GROSS, NET, PRIM, SEC, and TER select gross or net weight display, and primary,

secondary, or tertiary units display modes.

• CLRTAR clears the current tare for the active scale.

• CLRACC clears the active accumulator.