Using Revolution

51

5.2

Installing Software Upgrades

New releases of the

720i

system software can be

downloaded and installed using an internet connection
and the Rice Lake Web Update application. To use the
Web Update application, install the program

from the

Tool Kit CD.

Note

Before upgrading to a new version of

720i

system software, ensure that a copy of the
current indicator configuration has been saved
using

Revolution III

as these are not

interchangeable. Reloading the system
software requires a RESETCONFIGURATION
function and resets all configuration and
calibration values to their factory defaults.

Figure 5-1. Rice Lake Web Update Display

Click on the

Check for Updates

button in the Rice Lake

Web Update application to check if a new version of
the

720i

software (either 720i or 720i Batching) is

available. To download a new software version, select
the new software version and click on

Get Selection

.

Once the new software is downloaded to the PC, do the
following:

1. Disconnect power to the

720i

.

2. Open the indicator enclosure and place a

jumper across the SW1 boot mode pins (see
Figure 2-3 on page 9).

3. Connect the PC serial port to port 2 of the

720i

.

4. Power up the

720i

. The indicator will stall at

the diagnostic monitor.

5. Click on the

Update Indicator

button to

d o w n l o a d t h e n e w s o f t w a r e . W h e n t h e
download is complete, the indicator resets and
goes to weigh mode.

6. Disconnect power to the indicator. Remove the

jumper from the SW1 boot mode pins and
place it on a single pin.

7. Power up the indicator and reload as necessary.