78

720i Installation Manual

DIGOUT

bit_number

Lists all digital output bits available for the specified SLOT. This parameter is used to
specify the digital output bit associated with this setpoint. Use the DIG I/O menu to
assign bit function to OUTPUT.

For continuous setpoints, the digital output becomes active (low) when the condition
is met; for batch setpoints, the digital output is active until the setpoint condition is
met.

BRANCH

0
1-32

Specifies the setpoint number to which the batch sequence is to branch if the current
setpoint is not satisfied upon initial evaluation.

The special value zero indicates that no branch is taken.

TIME

time

For TOD setpoints, specifies the time at which the setpoint becomes active. The
format used to enter the time (12-hour or 24-hour) is based on the value specified for
the TIMEFMT parameter on the FEATURE menu.

DURATION

hh:mm:ss

For TOD setpoints, specifies the length of time that the digital output associated with
this setpoint changes state. The value is entered in hours, minutes, and seconds
(hh:mm:ss). All other operations associated with this setpoint (print, tare, or
accumulate) are performed at the end of the specified duration.

VUNDER

0–9999999

For CHKWEI setpoints, specifies the lower weight limit.

VOVER

0–9999999

For CHKWEI setpoints, specifies the upper weight limit.

DUNDER

digital_output

For CHKWEI setpoints, specifies the bit number of digital output activated when the
scale weight is less than the VUNDER value specified.

DACCEPT

digital_output

For CHKWEI setpoints, specifies the bit number of digital output activated when the
scale weight between the VUNDER and VOVER values specified.

DOVER

digital_output

For CHKWEI setpoints, specifies the bit number of digital output activated when the
scale weight is greater than the VOVER value specified.

SENSE

NORMAL
INVERT

Specifies whether the value of the digital output associated with this setpoint is
inverted when the setpoint is satisfied.

SETPTS Menu

Parameter

Choices

Description

Table 8-2. Setpoint Menu Parameters (Continued)