Serial Commands

87

10.1.2

Reporting Commands

Reporting commands send specific information to the
serial port. The commands listed in Table 10-2 can be
used in both setup mode and normal mode.

Table 10-2. Reporting Commands

Command

Function

DUMPALL

List all parameter values

DUMPAUDIT

List audit trail information

SPDUMP

Print

PCEE

configuration

VERSION

Write

720i

software version

HARDWARE

Lists installed option cards. See
Section 11.1.2 on page 99 for more
information about using the HARDWARE
command.

XE

Returns a 10-digit code representing any
error conditions currently shown on the
front panel. See Section 11.1.5 on
page 100 for more information.

10.1.3

Clear and Reset Commands

The following commands can be used to clear and reset
the

720i

:

RS

: Reset system. Resets the indicator without

resetting the configuration.

RESETCONFIGURATION

: Restores all configuration

parameters to their default values (setup mode
only). The

RESETCONFIGURATION

function can

also be initiated by pressing the

Reset Config

softkey under the VERSION menu. Use the

up

key

to select

Clear entire indicator configuration

, then press

Enter

to reset the indicator.

Note

All load cell calibration settings are lost when
the RESETCONFIGURATION command is run.

10.1.4

Parameter Setting Commands

Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 10-3 through 10-10).

Current configuration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:

command<ENTER>

Most parameter values can be changed in setup mode
only.

Use the following command syntax when changing
parameter values:

command=value<ENTER>

, where

value

is either a number or a parameter value. Use no spaces
before or after the equal (=) sign. If you type an
incorrect command, the display reads

??

.

For example, to set the motion band parameter on Scale
#1 to 5 divisions, type the following:

SC.MOTBAND#1=5<ENTER>

For parameters with selectable values, enter the
command and equal sign followed by a question mark:

command=?<ENTER>

to see a list of those values. The

indicator must be in setup mode to use this function.

Note

Some parameters are valid only if other
parameters or parameter values are specified.
See the configuration menus in Section 3.2 on
page 20 for information
about parameter
dependencies. Restrictions for front-panel
configuration also apply to serial command
configuration.

Command

Description

Values

SC.GRADS#1

Graduations

1–9999999

SC.SPLIT#1

Multi-range or multi-interval scale type

OFF, 2RNG, 3RNG, 2INTVL, 3INTVL

SC.ZTRKBND#1

Zero track band

0, 0–100

SC.ZRANGE#1

Zero range

1.900000, 0–100

SC.MOTBAND#1

Motion band

1, 0–100

SC.SSTIME#1

Standstill time

1–65535

SC.OVRLOAD#1

Overload

FS+2%, FS+1D, FS+9D, FS

SC.WMTTHRH#1

Weighment threshold

grads

SC.NUMWEIGH#1

Number of weighments

SC.MAX_WEIGHT#1

Maximum weight

SC.DIGFLTR1#1
SC.DIGFLTR2#1
SC.DIGFLTR3#1

Digital filtering

1, 2, 4, 8, 16, 32, 64, 128, 256

SC.DFSENS#1

Digital filter cutout sensitivity

2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT

Table 10-3. SCALES Serial Commands