Rice Lake 720i Programmable Indicator/Controller - Installation Manual User Manual

Page 86

Advertising
background image

80

720i Installation Manual

To begin a batch process, turn the 3-way switch to

START

momentarily. If the STOP button is pushed

during the batch process, the process halts and the
button locks in the IN position.

The

START

switch is ignored while the STOP button is

locked in the IN position. The STOP button must be
turned counterclockwise to unlock it, then released into
the OUT position to enable the 3-way switch.

To restart an interrupted batch from the step where it
left off, do the following:

1. Unlock STOP button (OUT position)

2. Turn 3-way switch to

START

To restart an interrupted batch from the first batch step,
do the following:

1. Turn 3-way switch to

ABORT

2. Unlock STOP button (OUT position)

3. Turn 3-way switch to

START

Note

Use this procedure (or the BATRESET serial
command) to initialize the new batch routine
following any change to the setpoint
configuration.