Using ProAction PCEE

83

To create this process:

1. Install both the PCEE program and the DBE program.

2. Open the PCEE program.

3. Click

New Step

button.

The Step dialog box appears.

4. In the Step Name text box, type the desired name for this step.

5. Ensure

Auto-Sequence

is checked.

6. Click

OK

.

The step will appear in the left column and the Auto Sequence will add the

Deactivate

for this step and an

Activate

for the next step.

7. Click on

Enable

to set the default to Enabled for this step.

8. Under Available Conditions, click on

Digital Input Compare

and click the

Left Arrow

button.

This will use a DigIn to start this process.

9. Select

bit 1

in the parameter section and

ON

for

Target State

.

10. Using

Revolution III

, ensure that

DIO bit 1

on

Slot 0

is set to

INPUT

.

11. Click

New Step

to create the second step and name it.

12. Under Available Conditions, click on

Weight Compare

and click the

Left Arrow

button.

13. Set the parameters to

Higher

and a value of

100

. We won’t use a Preact for now. This is our fill step.

14. Select the “True Actions” tab.

15. Click

Digital Output

and click the

Left Arrow

button.

16. In the parameters, set to

bit 2

and

OFF.

This will turn our relay off when the target is reached.

17. Select the “False Actions” tab.

18. Click

Digital Output

and click the

Left Arrow

button.

19. Set the parameters to

bit 2

and select

ON

. This will turn our relay on until the target is reached.

20. Using

Revolution III

, ensure that DIO bit 2 is set to

OUTPUT

.

21. Click the

New Step

button for the final step and name it.

22. Under Available Conditions, click on

Weight Compare

and click the

Left Arrow

button.

23. Set the parameters to

Lower

and a value of

5

. This is our Dump step.

24. Under Step 3’s true actions, adjust the

Activate

to

Step 1

instead of Step 4. Auto Sequence will continue to

enable a next step; however, if there is no next step, we need to change the activate back to our first step.

25. From the Tools menu, select

Validate

to check the process steps for any basic errors.

26. From the File menu, select

Save As...

and select a file name and save location.