Making a Multi-Track Recording

CONDITION MARKER#

bVb Surf acebcan— Uff

UEAKJRE BEAT

T

Surface Scan

This confirms that the read and write functions in all of the disk drive's

partitions are operating correctly when the drive is initialized. In normal

circumstances, set this to "On."

Press

[YES (ENTER)].

"SYS Init.***:* OK ?" appears in the

display. "***:*" refers to the drive's SCSI ID number. For

example, "IDE:0" indicates a internal hard disk.

Press

[YES (ENTER)]

again. "SYS Init.^=*H=::.=, Sure ?" (Really

initialize the disk?) appears in the display.

Press

[YES (ENTER)]

again. If any songs to which Song

Protect has been applied remain on the hard disk, the

messages "Found ProtectSng" and "Init.Continue?" alternate in

the display.

If you wish to save the current song, press

[YES (ENTER)];

if

not, then press

[NO (CANCEL)].

The Surface Scan procedure

takes a certain amount of

time. Be aware that

initializing a drive requires

some time. This is not a

malfundon. For example,

when physical formatting

is turned on, the time

required to format one

2jp

disk is approximately 10

minutes. The progress of

initialization will be shown

in the display. Be sure not

to turn the power off until

initialization is complete.

After the initialization is completed correctly, the VS-890

restarts automatically, and return to Play condition.