Entering programming mode

Enter programming mode on site from an alphanumeric touchpad using an
installer/dealer code (default = 4321). The system can be put into program mode
only when it is disarmed.

To enter programming mode using an alphanumeric touchpad connected
to the panel terminals:

1. Make sure the system is disarmed.

2. Press 8 + CODE + 0 + 0. The touchpad shows SYSTEM PROGRAMMING.

Note

: If the programming touchpad is connected before the panel is powered

up, it will be added (learned) into panel memory as a permanent touchpad.

To enter programming mode using a programming touchpad:

1. Connect the red, black, green, and white wires from the Programming

Touchpad Cable (60-791) to the power and bus wires on an alphanumeric
touchpad while matching the wire colors on each.

2. Make sure the system is powered up and disarmed.

3. Connect the plug on the cable onto the panel programming touchpad header

(see Figure 20 below).

Figure 20: Connecting a programming touchpad

4. Press 8 + 4321 + 0 + 2. The touchpad sounds one short beep and the display

shows a flashing star. Press * and the display shows SERVICE TOUCHPAD
ACTIVE.

5. Press 8 + 4321 + 0 + 0 and the display shows SYSTEM PROGRAMMING.