Siren Verify (0610)

Siren Options-Partition 1 (Default=off)

This setting determines whether or not the
panel monitors sirens connected to panel
terminal 7 (OUT1/+12V).

When this feature is on, sirens connected to
panel terminals 3 (GND) and 7 (OUT1/+12V)
require a 2k end-of-line resistor. Refer to
“Installing the System—Connecting Sirens” for
complete details.

Note

: For UL Listed systems, this feature must

be on.

To turn Siren Verify off or on:

1. With the display showing SIREN VERIFY

OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered setting.

2. Press # and the display shows the new

setting.

Sensors Menu

Note

: If 2-wire smoke detectors are connected to hardwire zone input 6, the Two-

wire Smoke setting must be turned on before entering the LEARN SENSORS
menu. See ONBOARD OPTIONS—INPUTS.

The SENSORS menu gives you access to the following:

• LEARN SENSORS—lets you learn hardwire zones and wireless sensors into

panel memory and assign zones/sensors to specific partitions.

• SENSOR TEXT—lets you program sensor text for zone/sensor identification.

• DELETE SENSORS—lets you delete zones/sensors from panel memory.

• EDIT SENSORS—lets you view and/or change sensor/zone group

assignment, view sensor number and text assignments of learned
sensors/zones, identify whether zone is wireless or hardwire, and indicates
sensor/zone/touchpad input N/C or N/O configuration.

The following describes how to program the sensor settings that appear under
LEARN SENSORS.