Activity Timeout (0305)

Timers-Global (Default=24 hours)

This setting determines when the system
sends a “no activity” report. The panel can
be set to wait from 1-42 hours. If no user
interaction or device activation occurs in
that time, the panel sends a report to the
central station.

To set the Activity Timeout:

1. With the display showing ACTIVITY TIMEOUT

nn HOURS (current setting) enter the desired 2-
digit time value (1-42). The display flashes the
entered setting.

2. Press # and the display shows the new setting.

Daylight Savings (0306)

Timers-Global (Default=on)

This setting determines whether or not the
panel clock automatically adjusts for
daylight saving time changes in spring and
fall.

To turn Daylight Savings off or on:

1. With the display showing

DAYLIGHT SAVINGS

OFF/ON

(current setting)

, press 1 (off) or 2 (on).

The display flashes the entered setting.

2. Press # and the display shows the new setting.

The following describes how to program the Timer settings that appear under
PARTITION 1.

Entry Delay (0310)

Timers-Partition 1 (Default=30 sec.)

This setting determines how much time (30-240
seconds) users have to disarm the system
(after entering the armed premises through a
designated delay door) to avoid causing an
alarm.

Note

: For UL Listed residential installations, the

Entry Delay must be set to 45 seconds or less.
The combined time for the Entry Delay and
Dialer Abort Delay (02006) must not exceed 60
seconds.

To set the Entry Delay:

1. With the display showing ENTRY DELAY

nnn SECONDS (current setting), enter the
desired time value (30-240 using 8-second
intervals). The display flashes the entered
setting.

2. Press # and the display shows the new

setting.

Exit Delay (0311)

Timers-Partition 1 (Default=60 sec.)

This setting determines how much time (45-
184 seconds) the user has to leave the
premises through a designated delay door
(after arming the system) without causing
an alarm.

Note

: For UL Listed residential installations,

the Exit Delay must be set to 60 seconds or
less.

To set the Exit Delay:

1. With the display showing EXIT DELAY nnn

SECONDS (current setting), enter the desired
time value (45-184 using 8-second intervals).
The display flashes the entered setting.

2. Press # and the display shows the new setting.